  1. Server operations

    RAID 0 vs 1 vs 5 vs 10: one comparison table, then choose by workload

    RAID 0 vs 1 vs 5 vs 10 differs in how data is made redundant. RAID 0 only stripes; RAID 1 mirrors two drives; RAID 5 spends one drive on parity, cheap per TB but slow on small writes and rebuilds; RAID 10 mirrors then stripes for steady random writes. Databases and VMs: RAID 10. Boot drives: RAID 1.

    10 min read
  2. Networking & IP

    What is an IP address? Format, classes and how it works

    An IP address is the number that identifies a network interface. IPv4 addresses are 32 bits written as four decimals, like 192.168.1.10: the network portion says which network, the host portion which device. Routers read the network portion; the MAC address handles the last hop.

    11 min read
  3. Server operations

    1U vs 2U server: what actually differsand which one to buy

    In a 1U vs 2U server comparison, CPU and memory are normally identical. The difference is what the extra 1.75 inches holds: 2–3 times the drive bays and PCIe slots, larger, quieter fans and higher-wattage power supplies, at the cost of a second rack unit. Web nodes go 1U; storage and GPU go 2U.

    8 min read
  4. Networking & IP

    What is IPv6? Address structure, benefits and adoption

    IPv6 is version 6 of the Internet Protocol and the successor to IPv4. It extends addresses from 32 to 128 bits, enough for every network segment to be a /64, and removes the need for layers of NAT. The catch: it cannot talk to IPv4 directly, so the two will coexist for years.

    10 min read
  5. Networking & IP

    VLAN types: port, MAC, protocol and subnet-based membership compared

    By how membership is assigned, there are four VLAN types: port-based, MAC-based, protocol-based and IP subnet-based. Port-based is set by the switch admin; the other three follow the device, so a host can change VLAN by changing its own MAC or IP. That is why data centers use port-based VLANs.

    10 min read
  6. Networking & IP

    What is CIDR? Classless routing and slash notation explained

    What is CIDR? Classless Inter-Domain Routing replaced Class A, B and C networks in 1993: the network part of an address is no longer fixed at 8, 16 or 24 bits but written after a slash. A /22 fixes the first 22 bits and leaves 10 free, a block of 1,024 addresses.

    10 min read
  7. Networking & IP

    What is SNMP? How managers, agents and MIBs work together

    SNMP (Simple Network Management Protocol) is an IETF protocol that monitoring systems use to read device status and devices use to send alerts. It has three parts: the manager that queries, the agent on the device, and the MIB that defines what can be read. Most networks run v2c or v3.

    10 min read
  8. Networking & IP

    What is a VLAN? How one switch is split into separate broadcast domains

    A VLAN (virtual LAN) groups switch ports under a number, and each group is its own broadcast domain: ports in one VLAN talk at Layer 2 as usual, while different VLANs cannot see each other. That number is the VLAN ID, 1 to 4094; on links shared by several VLANs, an 802.1Q tag carries it.

    10 min read
  9. Security & compliance

    What is a DDoS attack? How it works, the three types and what you see when you are hit

    What is a DDoS attack? A distributed denial of service attack makes many devices spread across the internet flood one target at once, exhausting its bandwidth, connections or CPU so real users cannot get in. It steals no data and breaks into nothing: it attacks availability.

    7 min read
  10. Server operations

    How to enable PXE boot in BIOS: UEFI and legacy settings by server brand

    To enable PXE boot in BIOS, turn on network boot for the NIC port (Network Stack or PXE Device in UEFI mode, the PXE option ROM in legacy mode), pick IPv4 or IPv6, and put the NIC in the boot order, or press F12 at POST to network boot once. Miss one and the NIC never appears.

    11 min read
  11. Networking & IP

    How to find my IP address: local, private and public IP explained

    How to find my IP address depends on which one you need. Your local IP sits on the network adapter: run ipconfig on Windows, ip addr on Linux or show ip interface brief on a switch. Your public IP is what internet servers see and can only be checked from outside. If they differ, NAT sits in between.

    10 min read
  12. Data center

    PDU vs power strip: current, construction and safety

    A rack PDU is the last stage of power distribution: it runs on a 16 A, 32 A or three-phase circuit, is fixed to the rack and can meter and switch outlets. A power strip is sized for one household outlet. A PDU can act as a power strip if the plugs fit; a strip does not belong in a server rack.

    8 min read
  13. Server operations

    What is HPE iLO? Remote management for ProLiant servers explained

    HPE iLO (Integrated Lights-Out) is the BMC built into ProLiant servers: a separate chip with its own network port that lets you power the host on and off, see its screen and mount an ISO with nobody on site. What you can do depends on the iLO generation and the license.

    13 min read
  14. Server operations

    What is IP KVM? How KVM over IP works, its three forms and when you need one

    What is IP KVM? Hardware that puts a computer's screen, keyboard and mouse on the network: it streams the video output to your browser and feeds your input back as USB. Because it works outside the OS, you can operate POST, the BIOS, installers and blue screens remotely.

    9 min read
  15. Data center

    What is a PDU? Rack power distribution units: role, types and specs

    In a data center, PDU stands for power distribution unit: a strip in the rack that splits one upstream circuit across the equipment, adding protection, metering and remote control. In networking, PDU means protocol data unit, which has nothing to do with power.

    11 min read
  16. Data center

    What is PUE? Data center power usage effectiveness explained

    PUE (power usage effectiveness) = total data center energy ÷ IT equipment energy. A PUE of 1.5 means each kWh used by IT equipment costs another 0.5 kWh for cooling, power losses and lighting. Closer to 1.0 is better, but PUE only measures how efficiently power reaches IT, not how well IT uses it.

    10 min read
  17. Server operations

    What is PXE boot? How network booting and PXE installs work

    PXE (Preboot eXecution Environment) is network booting built into NIC firmware. A server with no OS asks DHCP for an address and a boot file name, downloads a bootloader over TFTP and runs it from memory. A PXE install uses that path to deliver the installer and an answer file, with no USB stick.

    11 min read
  18. Security & compliance

    ARP spoofing attack explained: how it works, what it damages and how to spot it in a data center

    An ARP spoofing attack sends forged ARP replies on a layer 2 segment so other hosts map the gateway's or a server's IP to the attacker's MAC. ARP has no authentication, so no exploit is needed; one compromised server can take a whole VLAN down, hijack traffic or steal IPs.

    10 min read
  19. IDC business & buying guides

    How automated server provisioning works: from paid order to delivered server

    Automated server provisioning is an order state machine: a payment reserves a free server, then IP assignment, switch port setup, a PXE reinstall over IPMI and credential delivery run in a fixed order. Each step must detect failure and release what it took, or servers stay half-provisioned.

    13 min read
  20. Data center

    19 inch rack standard: what the 482.6 mm width really measures

    In the 19 inch rack standard, 19 inches (482.6 mm) is the equipment panel width, not the cabinet. Rail holes are 465.1 mm apart, the opening is 450.85 mm, cabinets are usually 600 or 800 mm wide, and 1U = 44.45 mm with three holes per U.

    9 min read

Ready to put your IDC on autopilot?

Start with a product demo and map out your next step.

View pricing
Hotline 400-112-2951

Let’s talk about your IDC

Scan with WeChat to book a product demo or request a trial.

Toplink WeCom contact QR code

Save this code or scan it with WeChat / WeCom

Or call
400-112-2951
Telegram
@TopLink88